Industry news

Seamless Alloy Steel Tube,petro-chemical,ASTM A53
BackYou are in :  Home  >  News  >  Industry news

Internal Anti-corrosion Treatment Methods for Large-Diameter Spiral Steel Pipes

Date:2025-12-15View:1203Tags:Seamless Alloy Steel Tube,petro-chemical,ASTM A53

Generally speaking, cement mortar coating should be carried out after the installation of spiral steel pipes, pressure testing, backfilling and compaction, and meeting the design requirements.

This is because spiral steel pipes have low stiffness and thin wall thickness, and the pipeline must be in a stable state during coating construction. If coating construction is carried out before laying, significant deformation may occur during lifting, transportation, and backfilling, which may damage the anti-corrosion layer.

Before coating construction, the inner wall of the spiral steel pipe must be cleaned to remove loose rust, dirt, scale, grease, welding slag, and other attachments. The protrusion of the inner wall of the spiral steel pipe shall not exceed one-third of the design thickness of the anti-corrosion layer; The vertical deformation of the pipeline shall not exceed the design specifications and shall not exceed 2% of the inner diameter of the spiral steel pipe.
The anti-corrosion layer inside cement mortar can be constructed by mechanical spraying, manual plastering, pipe dragging construction, or centrifugal prefabrication. If the internal anti-corrosion layer needs to be prefabricated, protective measures should be taken during transportation, installation, and backfilling. The first step of construction is to mix cement mortar. The mass ratio of cement to sand should be 1: (1-2), the slump of cement mortar should be 60-80 millimeters, and the compressive strength should not be less than 30 megapascals.
Mechanical spraying can form a smooth, dense, and uniformly thick internal anti-corrosion layer of cement mortar, with good results. Mechanical spraying technology began in the 1930s abroad, and in China, cities such as Shanghai, Qingdao, and Dalian began adopting it in the 1960s. When using mechanical spraying, bends, tees, special steel pipe fittings, and pipe sections near gate valves can be manually sprayed and smoothly transitioned with the mechanical spraying layer.
Other methods, such as the drag tube method or centrifugal prefabrication method, have also been widely used, but this article will not discuss them in detail. Regardless of the construction method used, the curing process is a key step in ensuring that the internal anti-corrosion layer of cement mortar does not crack or hollow out. Therefore, after the formation of the cement mortar anti-corrosion layer, the steel pipe must be immediately sealed to prevent air convection; After its final solidification, it should be wetted and cured. Generally speaking, the curing time for Portland cement should not be less than 7 days, and the curing time for slag Portland cement should not be less than 14 days; Before supplying water, it should be continuously sealed and kept moist.